LK Automation Limited
Home >> Products >> OMRON >> Power/other peripheral devices >> Power Supply >> Switching power >> S8EX-BP24024LC Output current: 10 A (100 VAC) 125 A (200 VAC) OMRON S8EX-BP24024LC

S8EX-BP24024LC Output current: 10 A (100 VAC) 125 A (200 VAC) OMRON S8EX-BP24024LC

Brand: OMRON
Name: Switch Mode Power Supply
Model: S8EX-BP24024LC
Power ratings: 240 W.
Output voltage: 24 V.
Output current: 10 A (100 VAC) 12.5 A (200 VAC).
Boost current: 20 A.
Newly Released High-capacity 240-W Models in S8EX-series Lineup.
Rated Output of 300 W for 200 VAC.
From 170 to 264 VAC.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models.
Lineup of models with from 5 to 48-VDC output.
voltages.
All Models.
Approved standards:
UL60950-1, cUR CSA C22.2 No. 60950-1, EN 50178,
and EN 60950-1.
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC.
Complies with harmonic current standard in EN.
61000-3-2 (50-W to 240-W models).
The top class in industry for compact size.
Boost current output (some models excluded).

Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 50 W.
Output voltage: 12 V.
Output current: 4.2 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V) OMRON S8EX-BP24024LC.
Easy Mounting: Front-mounted type, DIN rail-mounted type are available S8EX-BP24024LC
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA) OMRON S8EX-BP24024LC.
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).Power rating: 50 W.
Input voltage: 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC*1).
Output voltage: 12 V VDC.
Output current: 4.2 A.
Built-in fan: None.
Model with terminal block facing forward OMRON S8EX-BP24024LC.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage OMRON Switch Mode Power Supply.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life OMRON Switch Mode Power Supply. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models) OMRON Switch Mode Power Supply.
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation S8EX-BP24024LC.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON S8EX-BP24024LC. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.


...More relevant models >>>>