LK Automation Limited
Home >> Products >> OMRON >> Master slave station products >> DeviceNet >> OMRON DRT2-MD16TA-1 Transistor Remote I/O Terminals with 3-tier Terminal Blocks OMRON DRT2-MD16TA-1

OMRON DRT2-MD16TA-1 Transistor Remote I/O Terminals with 3-tier Terminal Blocks OMRON DRT2-MD16TA-1

Brand: OMRON
Name: Transistor Remote I/O Terminals with 3-tier Terminal Blocks
Model: DRT2-MD16TA-1
Specifications: I/O; PNP (input: - common,
output: + common)); Input:
8 points/Output: 8 points.
I/O connections: M3 screw terminals.
Rated internal circuit power supply voltage:
Supplied from Basic Unit.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals.
Easy wiring with no sharing of terminals.
Easy-to-understand wiring locations.
No relay terminal block terminals required.
Detachable cassette-type circuit sections.

Input capacity: 32 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the G terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common OMRON DRT2-MD16TA-1.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation DRT2-MD16TA-1
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 100 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 210 g max.
Expansion functions: No OMRON DRT2-MD16TA-1.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing OMRON DRT2-MD16TA-1.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance. Name: Expansion Units.
Specifications: inputs ;
16 inputs; NPN;
One Expansion Unit can be,
mounted to one CRT1-ID16(-1),
CRT1-OD16(-1), CRT1-ROS16,
or CRT1-ROF16 Digital I/O Slave OMRON Transistor Remote I/O Terminals with 3-tier Terminal Blocks OMRON Transistor Remote I/O Terminals with 3-tier Terminal Blocks.
Standards: CE, UC, UC1, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON Transistor Remote I/O Terminals with 3-tier Terminal Blocks.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: Outputs; NPPN (- common); 16 points DRT2-MD16TA-1.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Termminals OMRON DRT2-MD16TA-1.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H).