LK Automation Limited
Home >> Products >> OMRON >> CJ2/CJ1 PLC >> Basic I/O unit >> output unit >> OMRON CJ1W-OD234 Current consumption: 5V, 010A 24V, -- Output Units CJ1W-OD234

OMRON CJ1W-OD234 Current consumption: 5V, 010A 24V, -- Output Units CJ1W-OD234

Brand: OMRON
Name: Output Units
Model: CJ1W-OD234
Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 32 outputs(High speed);
Maximum switching capacity, 24VDC, 0.5A;
Commons, 16 points, 1 common;
External connection, MIL connector.
No. of words allocated: 2 words.
Current consumption: 5V, 0.22A; 24V, --.
Standards: N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput.

Product name: AC Power Supply Unit.
Power supply voltage: 100 to 240VAC.
Output capacity: 5-VDC output capacity, 5A;
24-VDC output capacity, 0.8A;
Total power consumption, 25w.
Options: 24-VDC service power supply, No;
RUN output, Yes; Maintenance forecast monitor, No.
Standards: UC1, N, L, CE OMRON CJ1W-OD234.
Equipped with the RUN output for,
checking the operation status,
as well as the replacement CJ1W-OD234
notification function for easy,
maintenance.
Lineup of five models including the,
AC power supply (25W).
Stable power supply is available from the,
CJ-series CPU Unit to each I/O Units via the,
dedicated bus. The most suitable Power Supply,
Unit can be selected among various I/O ,
specifications and/or options OMRON CJ1W-OD234. Unit type: CJ1 CPU Bus Units.
Product Name: Position Control,
Unit with MECHATROLINK-II interface.
Specifications: Control commands,
executed by MECHATROLINK-II,
synchronous communications.
Direct operation by ladder programming.
Control mode: Position control,
speed control or torque control;
No. of axes: 2 axes.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0 OMRON CJ1W-OD234. 36A; 24V,--.
Standards: UC1, CE.
Decrease TCO with Simple Operation,
Reduced Wiring, Batch Settings,
and Batch Management.
Control Servos for up to 16 axes in,
a motion network with one Position,
Control Unit that supports MECHATROLINK-II OMRON Output Units.
MECHATROLINK-II is a registered trademark,
of the MECHATROLINK Members Association. Unit type: CJ1 CPU Bus Unit.
Product Name: Ethernet Unit OMRON Output Units.
Specifications:Communications cable,
100Base-TX; Communications functions,
FINS communications service(TCP/IP, UDP/IP),
FTP server functions, socket services,
mail transmission service,
mail reception (remote command receive),
automatic adjustment of PLC''s built-in clock,
server/host name specifications;
nits per CPU Unit: 4 OMRON Output Units.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.37A; 24V,--.
Standards: UC1, N, L, CE.
Organically Connect the Production,
Site and Management Select the required,
communications services according to,
application needs to flexibly integrate,
PLCs with an Ethernet information network. Unit classification: CJ1 Special I/O Units.
Product name: Isolated type DC Input Units.
Input points: 2 inputs.
Signal range selection: DC voltage:
0 to 1.25 V, -1.25 to 1.25 V, 0 to 5 V,
1 to 5 V, -5 to 5 V, 0 to 10 V, -10 to 10 V,
±10 V selectable range DC current:
0 to 20 mA, 4 to 20 mA.
Conversion speed (resolution): Conversion,
speed: 10 ms/2 inputs, Resolution: 1/64,000.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0.05% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
CCurrent consumption: 5V, 0 CJ1W-OD234. 18A; 24V, 0.09A.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inpuut channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) OMRON CJ1W-OD234.
All inputs are isolated.