LK Automation Limited
Home >> Products >> OMRON >> Relay >> General relay >> Special action relay >> MYA-NA2 Contact alarm relay circuit unit OMRON MYA-NA2

MYA-NA2 Contact alarm relay circuit unit OMRON MYA-NA2

Brand: OMRON
Name: Contact alarm relay circuit unit
Model: MYA-NA2
Action mode alarm contact: no lock, a contact.
Category: auxiliary contact.
Relay number: 2.
Relay circuit unit suitable for centralized alarm device of various control circuits.
MYA combination of multiple MY4 micro power relay, with all kinds of alarm function.
Small, socket type, so it can effectively use the space, repair, maintenance and other operation is simple and convenient.
By use, roughly divided into 4 types, to adapt to the full range of models.
Lloyd standard certified products (MYA-LA12, -LB12).

Terminal (wire connection): Push-In Plus Terminal.
Applicable output load: AC load.
Zero cross function: No.
Rated input voltage: DC 24V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel OMRON MYA-NA2.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals MYA-NA2
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires OMRON MYA-NA2.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Isolation: Phototriac coupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 20 A at 180 to 400 VAC.
Rated input voltage: 12 to 24 VDC.
Extremely Thin Relays Integrated with Heat Sinks OMRON MYA-NA2.
Downsizing achieved through optimum design of heat sink.
Mounting possible via screws or via DIN track.
Close mounting possible for linking terminals.
(Except for G3PA-260B-VD and G3PA-450B-VD-2.)
Applicable with 3-phase loads.
Replaceable power element cartridges OMRON Contact alarm relay circuit unit.
Comply with VDE 0160 (finger protection),
with a dielectric strength of 4,000 V between input and load OMRON Contact alarm relay circuit unit.
Certified by UL, CSA, and VDE (reinforced insulation). The main body: with shell type / socket terminal type.
Classification: internal connection special type, double contact.
Pole number: 2 pole.
A variety of eight pin pin type electric power.
With shell models have AC4 rated specifications (50/60Hz AC200/220V, 50/60Hz AC100/110V) OMRON Contact alarm relay circuit unit.
Installation, wiring convenient, easy to operate.
Has more than 5 million mechanical life, durable.
Standard type, with shell type, special contact specifications, double contact type, double coil latch type, etc., the product is complete. Contact form: SPST-NO.
Type: Models with Test Button and Built-in Operation Indicators.
Rated voltage: AC: 24, 100, 110, 120, 200, 220, 230, 240;
DC: 12, 24, 48, 110, 220.
MK-S-series Relays with DC-switching,
Models That Can Switch 220 VDC, 10 A,
(Resistive Load).
Switch a DC load of 220 VDC, 10 A (resistive load).
Models for AC Loads can switch 250 VAC, 15 A (resistive lload) MYA-NA2.
Lineup includes models with SPST-NO and SPST-NO/SPST,
NC contact forms.
Using a SPST-NO/SPST-NC contact form enables detecting,
contact welding. (When the NO contacts become welded, the,
NC contacts will maintain a minimum distance of 0 OMRON MYA-NA2. 5 mm.).
Models available with operation indicators and built-in test buttons.
RoHS compliant.
Standards: UL, IEC (TÜV certification).


...More relevant models >>>>