LK Automation Limited
Home >> Products >> OMRON >> Control equipments >> Digital panel table >> Pulse input >> K3HB-PNB-L2AT11 AC100-240 Time interval table OMRON K3HB-PNB-L2AT11 AC100-240 Action determine the color, can switch the green / Red 2 kinds of color display 

K3HB-PNB-L2AT11 AC100-240 Time interval table OMRON K3HB-PNB-L2AT11 AC100-240 Action determine the color, can switch the green / Red 2 kinds of color display 

Brand: OMRON
Name: Time interval table
Model: K3HB-PNB-L2AT11 AC100-240
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Linearity: voltage; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximum measurable

Set two time ranges between 1 and 120 s with one Timer.
Models with 240 to 440-VAC power supply added to series. Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Linear: current; NPN open collector (HH, H, PASS, L, LL) OMRON K3HB-PNB-L2AT11 AC100-240.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V K3HB-PNB-L2AT11 AC100-240
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend OMRON K3HB-PNB-L2AT11 AC100-240.
External event inputType: H5CX-L series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 OMRON K3HB-PNB-L2AT11 AC100-240 OMRON Time interval table.
External connections: 8-pin socket.
Input: Signal, Reset (NPN input).
Output: Contact output (time-limit SPDT) OMRON Time interval table.
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry. Timer input: No-voltage input.
Display: 7-segment LCD.
Time range: 999h59min59s ←→ 9999h59.9min(switchable); Light-gray body.
Seven digits, time range 0 to 3999d23.9h.
Dual time range: 999999 OMRON Time interval table. 9 ←→ 3999d23.9h or,
999h59m59s ←→ 9999h59.9m. Output: Transistor(Photocoupler).
Supply voltage: 24 to 48 VAC (50/60 Hz)/12 to 48 VDC.
Input type: No-voltage input.
Time range: 0.05 s to 300 h.
Operating mode (See note 2): Eight multi-modes: A, B, B2, C, D, E, G, J.
Multiple Operating Modes and Multiple Time.
Ranges. DIN 48 x 48-mm Multifunctional Timer.
A wide AC/DC power supply range greatly reduces the number,
of timer models kept in stock.
A wide range of applications with multiple operating modes,
eight modes for 11-pin mmodels and five modes for 8-pin models K3HB-PNB-L2AT11 AC100-240.
Ecological design with reduced current consumption.
Easy sequence checking with instantaneous outputs for a zero set value.
Length of 75 mm or less when panel-mounted with a P3G-08,
Socket (H3CR-A8E, 100 to 240 VAC, 100 to 125 VDC),
PNP input models available OMRON K3HB-PNB-L2AT11 AC100-240.
Standards: UL, CSA, NK, LR, CCC, EN 61812-1, and CE Marking.


...More relevant models >>>>