LK Automation Limited
Home >> Products >> OMRON >> Master slave station products >> EtherCAT remote I/O terminal >> GX-ID1611 OMRON EtherCAT Remote I/O Terminals OMRON GX-ID1611

GX-ID1611 OMRON EtherCAT Remote I/O Terminals OMRON GX-ID1611

Brand: OMRON
Name: EtherCAT Remote I/O Terminals
Model: GX-ID1611
Input capacity: 16 points.
Internal I/O common: NPN.
ON voltage: 15 VDC min.
(between each input terminal and the V terminal)
OFF voltage: 5 VDC max.
(between each input terminal and the V terminal)
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC);
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms, 1 ms,
2 ms, 4 ms, 8 ms, 16 ms, 32 ms (Default setting: 1 ms).
Number of circuits per common: 16 inputs/common.
Input indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current con sumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 180 g max.
Expansion functions: Enabled.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansion unit per one I/O terminal unit.)
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance.

Name: Analog I/O Slave Units.
Specifications: Analog outputs;
2 outputs.
Standards: CE, U, U1, C, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON GX-ID1611.
A wide variety of CompoNet Slave Units,
contribute to system size reduction GX-ID1611
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: Slice I/O Units; Analog I/O Units.
Specifications: Analog outputs (current) OMRON GX-ID1611.
Standards: CE, UC1, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site OMRON GX-ID1611.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. I/O classification: Digital output.
Internal I/O circuit common: PNP (+ common).
I/O points: 16.
I/O connection method: Sensor connector OMRON EtherCAT Remote I/O Terminals.
Compact Remote I/O Terminals that.
Save Wiring Effort and Enable.
Long-distance Communications.
Long-distance or high-speed communications,
mode is selectable OMRON EtherCAT Remote I/O Terminals.
Incorporates I/O connectors making it possible to,
minimize the size.
I/O connectors save wiring effort.
Flexible DIN track mounting is possible through a,
DIN track attachment.
Eight-point sensor connector models and 16-point,
MIL connector models are the same size OMRON EtherCAT Remote I/O Terminals. Input/Output: Outputs.
Internal I/O circuit common: PNP (+ common).
I/O points: 4 points.
I/O connection method: Sensor connector.
Rated voltage for I/O power supply: 24 VDC.
Eight Waterproof Terminal Models.
Emphasizing Cost Efficiency.
Reduced Labor.
Connection using connectors reduces the lead time,
required for installation. No tools are required for,
connection to a variety of devices.
Reduced Wiring.
Signal line wiring has been reduced so that the,
Terminal can be mounted closer to sensors and,
other devices.
Relay Box not Required.
Environment-resistant, dust-tight, drip-proof,,
construction (IP67) enables direct on-site,
mounting GX-ID1611.
Easier Maintenance.
Significant reductions not only in setup time but also,
maintenance time.
Reduced Space, Improved Operability,
Compact design (160 x 54 mm (W x H)) (88-point models) OMRON GX-ID1611.
Settings and connections can be performed using,
the switch and connectors on the front side of the Terminal.
System Configuration.