GX-AD0471 OMRON GX-AD0471

Brand: OMRON
Name: Analog I/O Terminal 2-tier Terminal Block Type
Model: GX-AD0471
Analog I/O terminal with screw terminal,
block for EtherCAT communicaitons.
The input/output range can be easily,
changed by the setting with the switch.
Detachable screw terminal block,
facilitates the maintenance.
Moving average calculation function.
Settings within the range of 100μs-64ms.
(For input only.)
Disconnection detection function.
(For input only and for usage with,
1-5V or 4-20mA ranges.)
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.

Name: MIL Connectors.
Specifications: Inputs/Outputs;
16 inputs/16 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON GX-AD0471.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site GX-AD0471
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Classification: Analog input.
I/O points: 4 inputs (Resolution: 30, 000).
Performs Calculations on Analog Values within the Slave Itself OMRON GX-AD0471.
Also Provides High Resolution at 1/30,000 (Full Scale) and,
Support for a Wide Variety of Data Sampling.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities.
Sampling data can be analyzed internally to provide a low-cost scheduler function.
Equipped with functions such as the scaling function, peak/bottom hold;
top/valley hold; comparator function, cumulative counter, and derivative,
calculation function OMRON GX-AD0471.
Two I/O points can be allocated to any two of the following values: analog,
input, peak/bottom, top, valley, or rate-of-change. Values without an,
allocated I/O point can be read with message communications OMRON Analog I/O Terminal 2-tier Terminal Block Type. Specifications: Outputs; PNP (+ common); 16 points.
I/O connections: MIL connector OMRON Analog I/O Terminal 2-tier Terminal Block Type.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces OMRON Analog I/O Terminal 2-tier Terminal Block Type.
35 x 60 x 80 mm (W x D x H). Name: System Units; End Unit *2.
Specifications: Necessary for,
terminating the Slice I/O Terminal.
Standards: CE, UC1, L, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cosst can be reduced GX-AD0471.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee OMRON GX-AD0471.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.