Brand: OMRON
Name: Electronic Thermostat
Model: E5L-A 100-200
Size: 45 × 35 mm.
Type: Plug-in.
Control method: ON/OFF operation.
Control output: Relay.
Power supply voltage: 100 to 240 VAC.
Ideal for Simple Built-in Control.
A high switching capacity of 10 A at 250 VAC enables,
direct load switching.
A sensor is provided to enable immediate application.
Sockets with finger protection (PTF14A-E) or without,
finger protection (PTF14A) can be used.
Simple operation and settings. Even simpler with digital models.

Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- OMRON E5L-A 100-200.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance E5L-A 100-200 Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks OMRON E5L-A 100-200.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors OMRON E5L-A 100-200.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 3.2 dia OMRON Electronic Thermostat.
Protective tubing length L: 15 cm.
Lead wire type: Standard.
Lead wire length M: 1m.
A Wide Variety of High-precision.
Temperature Sensors OMRON Electronic Thermostat.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON Electronic Thermostat. Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) mmakes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5L-A 100-200.
Through the infrared port can be carried out from the frront of the communication OMRON E5L-A 100-200.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.