LK Automation Limited
Home >> Products >> OMRON >> CJ2/CJ1 PLC >> High function I/O unit >> position control unit >> CJ1W-NC133 OMRON CJ1W-NC133 Position Control Units

CJ1W-NC133 OMRON CJ1W-NC133 Position Control Units

Brand: OMRON
Name: Position Control Units
Model: CJ1W-NC133
Unit classification: CJ1 Special I/O Units.
name: Position control unit.
Specifications; Control method/Control,
output interface:Open-loop control by pulse,
train output/Line-driver output;
Number of control axes : 1 axis.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, CE.
High-speed, High-precision positioning,
with 1, 2, or 4 axes.
Versatile functions and superb performance,
enable the construction of compact,
high-performance machines.
With its ultra-compact size of 31 × 90mm (W×H),
this highly space-efficient Position Control Unit,
(PCU) enables up to 4 axes of motor control.

Product name: CJ1M CPU Units; Without built-in I/O.
Specifications: I/O capacity/Mountable Units Expansion Racks),
320 points/10 Units (No Expansion Rack); Program capacity,
10K steps; Data memory capacity, 32K words(DM: 32K words, EM: None);
LD nstruction execution time, 0.1 μs.
Current consumption: 5v, 0 OMRON CJ1W-NC133. 58A (Seenote 1.) ; 24V,--.
Standards: UC1, N, L, CE.
Versatile Machine Control with the,
Highest Performance Standards in the Industry CJ1W-NC133 Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 4 loops;
Temperature sensor inputs: Platinum ,
resistance thermometer input(JPt100, Pt100);
Control outputs: Open collector NPN outputs (pulses) OMRON CJ1W-NC133.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output. Product name: CJ-series I/O Control Unit OMRON CJ1W-NC133.
Specifications: One I/O Interface Unit is,
required on each Expansion Rack.
Connecting Cable: CS1W-CN@@3 Expansion,
Connecting Cable Mount to the right of,
the Power Supply Unit.
Current consumption: 5V , 0.02A;
24V, --.
Standards: UC1, N, L, CE OMRON Position Control Units.
Expand CJ/NJ-series with These Units.
To expand a CJ/NJ-series Controller,
connect an I/O Control Unit to the CPU Rack,
and I/O Interface Unit to the Expansion Rack,
and connect the two Units with I/O Expansion Cable OMRON Position Control Units. Unit type: CJ1 Basic I/O Units.
Product name: DC Input/Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 32 inputs, 32 outputs;
Input voltage,Input current, 24VDC, 4.1mA,
12 to 24VDC, 0 OMRON Position Control Units. 3A;
Commons, 16 ppoints, 1 common;
External connection, Fujitsu connector CJ1W-NC133.
No. of words allocated: 4 words.
Current consumption: 5V, 0.14A; 24V, --.
Standards: UC1, N, CE.
A Wide Range of Basic Mixed,
I/O Units for Different Applications,,
and Wiring Methods OMRON CJ1W-NC133.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems.


...More relevant models >>>>