Standard certification: No.
Insulation mode: three end two-way photoelectric switch.
Zero trigger function: No.
Action indicator: No.
Applicable load of output: AC100 3A ~ 240V.
Input rated voltage: DC12V.
With the LY1, LY2 large power relay with the same shape of the G3H series, the new international standard certification (-VD type) OMRON Programmable Terminals HOST CONNECTION MANUAL.
Achieved UL, CSA, EN (VDE certification) standard certification
GT1-TS04T (type -VD)
Socket terminal type of same size with LY (1 pole, 2 pole type).
A model with an action indicator to check the status of the input. (type N)Terminal (Wire connection): Screw terminal.
Classification: Microloads.
Latching lever (Test switch): No.
Rated input voltage: AC/DC, 48V OMRON Programmable Terminals HOST CONNECTION MANUAL.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location) OMRON Programmable Terminals HOST CONNECTION MANUAL.
Screw terminal is also stocked to meet the screw type needs GT1-TS04T HOST CONNECTION MANUAL.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Isolation: Phototriac coupler.
Zero cross function: No GT1-TS04T HOST CONNECTION MANUAL.
Indicator: Yes.
Rated output load: 3 A at 100 to 240 VAC (See note 1.).
Rated input voltage: 5 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”) GT1-TS04T HOST CONNECTION MANUAL.
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix). Control terminal block: Terminal block with small slotted screws.
Type: Standard.
Capacity: 45 A, 100 to 240 VAC.
Heater burnout detection: No.
Communications: No.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 communications to set mmanipulated variables and,
monitor load current GT1-TS04T Manual.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control OMRON Programmable Terminals HOST CONNECTION MANUAL.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.