OMRON K3HB-XAA-T11 AC/DC24 datasheet PDF datasheet

Product model: K3HB-XAA-T11 AC/DC24
Name: Voltage and current panel meter
Brand: OMRON
Sort: PDF datasheet
File language: English
File size: 1.90MB
Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K3HB-XAA-T11 AC/DC24 datasheet.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K3HB-XAA-T11 AC/DC24
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XAA-T11 AC/DC24 datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase) K3HB-XAA-T11 AC/DC24 datasheet.
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Power supply voltage: 100 to 240 VAC.
Ideal for Liquid Level Control in.
Industrial Facilities and Equipment.
Self-holding circuit implemented with circuit processing that is,
not depending on external wiring.

Switch between water supply and discharge with a DIP switch setting K3HB-XAA-T11 AC/DC24 PDF datasheet.
Sensitivity adjustment of operating resistance from 10 k to 100,
kΩ for application to a wide range of liquids.
Prevents chattering of relay contacts that occurs with ripples K3HB-XAA-T11 AC/DC24 PDF datasheet.
Easy wiring with ferrules.
Use 2 × 2.5 mm2 solid wire or 2 × 1.5 mm2 ferrules.
Applicable as a floatless switch.
Related products
OMRON
Temperature panel
K3HB-HTA-T11 AC/DC24
OMRON Temperature panel K3HB-HTA-T11 AC/DC24
Type of input: platinum resistance / thermoco
OMRON
Voltage and current panel meter
K3HB-XAD-FLK3AT11 AC/DC24
OMRON Voltage and current panel meter K3HB-XAD-FLK3AT11 AC/DC24
Input type: DC current input. Output type: c
OMRON
Rotating pulse meter
K3HB-RPB-AT11 AC/DC24V
OMRON Rotating pulse meter K3HB-RPB-AT11 AC/DC24V
Input type: PNP input type. Event input term
OMRON
Time interval table
K3HB-PPB-FLK3AT11 AC/DC24V
OMRON Time interval table K3HB-PPB-FLK3AT11 AC/DC24V
Input type: PNP input type. Event input term