LK Automation Limited
Home >> Download >> OMRON >> Catalog Download >> OMRON K3HB-XVA-FLK1AT11 AC/DC24 PDF datasheet K3HB-XVA-FLK1AT11 AC/DC24 datasheet PDF catalog

OMRON K3HB-XVA-FLK1AT11 AC/DC24 PDF datasheet K3HB-XVA-FLK1AT11 AC/DC24 datasheet PDF catalog

Product model: K3HB-XVA-FLK1AT11 AC/DC24
Name: Voltage and current panel meter
Brand: OMRON
Sort: PDF datasheet
File language: English
File size: 1.90MB
Measuring voltage: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC.
Supply voltage: 24 VAC/DC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervoltages K3HB-XVA-FLK1AT11 AC/DC24 PDF datasheet.
Manual resetting and automatically resetting supported by one Relay K3HB-XVA-FLK1AT11 AC/DC24
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Category: external supply 100mA DC5V type K3HB-XVA-FLK1AT11 AC/DC24 PDF datasheet.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-XVA-FLK1AT11 AC/DC24 PDF datasheet.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event inputTime specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start off operation K3HB-XVA-FLK1AT11 AC/DC24 PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XVA-FLK1AT11 AC/DC24 PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Rotating pulse meter
K3HB-RNB-AT11 AC/DC24V
OMRON Rotating pulse meter K3HB-RNB-AT11 AC/DC24V
Input type: NPN/ voltage pulse input type. E
OMRON
Voltage and current panel meter
K3HB-XAA-L2AT11 AC/DC24
OMRON Voltage and current panel meter K3HB-XAA-L2AT11 AC/DC24
Type of input: AC current input. Output type
OMRON
Time interval table
K3HB-PNB-L1AT11 AC/DC24V
OMRON Time interval table K3HB-PNB-L1AT11 AC/DC24V
Input type: NPN/ voltage pulse input type. E