Product model: L06CPU-CM
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text Programming Manual
File language: English
File size: 4.20MB
Output points: 32 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 32 points (I/O distribution: output 32 points).
External wiring connection mode: 40 pin connector L06CPU-CM Programming Manual.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called L06CPU-CM
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol L06CPU-CM Programming Manual. Temperature measurement resistor input.
Number of input channels: 4ch.
Detection function of broken wire with heater.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode L06CPU-CM Programming Manual.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion MITSUBISHI L06CPU-CM Manual .
No idle running, with energy saving effect, can reduce operating costs.
Can make multi loop to reach the target value (SV) of the same time MITSUBISHI L06CPU-CM Manual .
By setting the simultaneous heating of the channel group, up to 2 groups of units, respectively, at the same time warming.
It is very effective to use the control object that does not want to heat up to the time of arrival error.
Applicable to a variety of systems MITSUBISHI L06CPU-CM Manual .
Sampling period switching function.
Sampling period can be selected from 250ms/4ch and 500ms/4ch.
Equipped with temperature input mode.
The temperature control module can be used as a temperature input module.
By setting the switch, you can easily change the input mode. Output points: 16 points.
Output type: leakage type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.5A/1 point.
Protection function: have.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
The switch input and output module is a device which can collect the input / output of thhe switch signal,
Digital I/O modules are often called L06CPU-CM Structured Text.
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can alsso be carried out through the RS-485 bus communication,
Remote control switch L06CPU-CM Programming Manual.
Communication protocol is a standard Modbus protocol or custom protocol.
Related products
MITSUBISHI
cpu module
L02SCPU-CM
MITSUBISHI cpu module L02SCPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L02CPU-CM
MITSUBISHI cpu module L02CPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L26CPU-CM
MITSUBISHI cpu module L26CPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L06CPU-CM
MITSUBISHI cpu module L06CPU-CM
"Universal output function: leakage type. Pro