LK Automation Limited
Home >> Products >> MITSUBISHI >> L series PLC >> CPU and accessories >> CPU >> L06CPU-CM MITSUBISHI GOT to GOT long distance connection cable L06CPU-CM

L06CPU-CM MITSUBISHI GOT to GOT long distance connection cable L06CPU-CM

Brand: MITSUBISHI
Name: cpu module
Model: L06CPU-CM
"Universal output function: leakage type.
Program capacity: 60K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ".
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators. "

Maximum transmission speed: 115.2kbps.
DC5V internal consumption current: 0.15A.
Weight: 0.12kg.
GOT connection.
MELSOFT connection.
Communication protocol support function serial communication function. "Universal output function: leakage type.
Program capacity: 20K step.
Basic operations processing speed: 40ns MITSUBISHI L06CPU-CM.
Communication interface: USB/Ethernet.
Control mode: stored procedure repeated operation L06CPU-CM
Input / output points: 1024 points.
End cap.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement MITSUBISHI L06CPU-CM.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ".
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s MITSUBISHI L06CPU-CM.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators. "Number of input channels: 8ch.
Input voltage: DC - 10 ~ 10V MITSUBISHI GOT to GOT long distance connection cable.
Conversion speed: 1ms/ch.
Resolution: 1/16000.
By shifting the function easily when the system starts to fine tune the movement function MITSUBISHI GOT to GOT long distance connection cable.
Shift the set value to (shift to) the function of the digital output value.
If you change the conversion value, the value is reflected in real time to the value of the scale (numeric value),
Can easily complete the fine-tuning of the system startup.
Extended detection method based on usage
Anomaly detection and extension of input signal
The detection method of the abnormal detection function of the input signal can be extended to detect the abnormal detection function of the input signal which is outside the rangge of the set range MITSUBISHI GOT to GOT long distance connection cable L06CPU-CM.
For the detection of the lower limit or the upper limit of the input signal abnormality, or when the detection of the broken line is performed.
Enter rannge extension
Range of scalable input range MITSUBISHI L06CPU-CM.
Combined with the abnormal detection function of the input signal, the broken line can be easily detected.


...More relevant models >>>>