MITSUBISHI Q25PRHCPU Manual Q25PRHCPU MELSAP-L Programming Manual

Product model: Q25PRHCPU
Name: PLC
Brand: MITSUBISHI
Sort: MELSAP-L Programming Manual
File language: English
File size: 3.16MB
Manual pulse generator /INC synchronous encoder input:
Use number: 3 sets of /1 modules.
Convenient processing of large capacity data.
In the past can not achieve the standard RAM and SRAM card file register area of continuous access,
The boundary of each area should be considered in programming.
The SRAM 8MB extension card is installed in the high speed universal QCPU,
Standard RAM can be used as a continuous file register,
Capacity up to 4736K words, thus simplifying the programming Q25PRHCPU Programming Manual Q25PRHCPU
Thus, even if the memory space of the soft element is insufficient,
Can also be installed by the expansion of SRAM card, easy to extend the file register area.
The address register is extended to 32 bits, which can be programmed to go beyond the traditional 32K word,
And to achieve the extension to the file register to all regions of the file register Q25PRHCPU Programming Manual.
In addition, the processing speed of the index modification plays an important role in the efficient operation of structured data (array),
The speed has been improved.
When the index is used to modify the program repeatedly (e.g. from FOR to NEXT), the scan time can be reduced Q25PRHCPU Programming Manual. 1 axes, open collector output type.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
Maximum pulse output: 200Kpps.
40 pin connector.
Positioning module.
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control.
(the command pulse of the open collector positioning module is highest 200kpps.) MODBUS RTU/MODBUS ASCII Master slave station.
RS-232.
RS-422/485.
MODBUS interface module capable of connecting MODBUS compatible device such as temperature regulator, measuring device and so on.
Support MODBUS communication function, and can be compatible with the third party MODBUS to communicate from various station equipment.
Support MODBUS communication functions from the station, can communicate with the third party programmable controller MODBUS master device.
Through the linkage function, the mmaster can be connected to the CH1 side (RS-232),
And through the QJ71MB91 and connected to the CH2 side (RS-422/485) of a number of stations for communication Q25PRHCPU Manual.
The RS-232 interface (1 credit on the 1 pass) MODBUS master device withh multiple MODBUS communication from the station equipment Q25PRHCPU Manual. (only QJ71MB91)
Master / slave station functions can be used simultaneously. (only QJ71MT91)
Related products
MITSUBISHI
Process CPU
Q12PHCPU
MITSUBISHI Process CPU Q12PHCPU
Program capacity: 124 K step. Input / output
MITSUBISHI
High performance CPU
Q25HCPU
MITSUBISHI High performance CPU Q25HCPU
Program capacity: 252 K step. Input / output
MITSUBISHI
With Ethernet CPU
Q06UDEHCPU
MITSUBISHI With Ethernet CPU Q06UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
CPU component
A1SJHCPU
MITSUBISHI CPU component A1SJHCPU
I/O control method: refresh mode or direct mo