A64BTL Manual MITSUBISHI A64BTL User's Manual

Product model: A64BTL
Name: Supersonic Linear Scale Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 1.72MB
Optional features of memory card (A/FX compatible).
4MB extended memory.
Applicable models: A985 (-V) /975/970/A960GOT (-B) /A956WGOT. Series Name: A953GOT.
Size: 6 inches.
Resolution: 320 * 240.
Display equipment: high brightness TFT color display.
Display color: 256 color.
Power supply: DC24V.
The built-in RS-232 communication interface MITSUBISHI A64BTL User's Manual.
Memory card: 1M.
Design any machine interface, generally have to consider the system response time, user assistance mechanism, error information processing and command mode four aspects A64BTL
System response time is too long to be the most users in the interactive system,
In addition to the absolute length of the response time, the user is also very concerned about the difference in response to different commands in response time,
If too wide users will be difficult to accept; user assistance mechanism should be integrated,
Avoid overlay systems that cause users to turn to a guide and have to browse a large number of irrelevant information;
Error and warning information must be selected in terms of user''s clarity and meaning,
At the same time, it should be as far as possible to provide some suggestions on the recovery of errors MITSUBISHI A64BTL User's Manual MITSUBISHI A64BTL User's Manual.
In addition, when the error message is displayed, the effect is better if it is supplemented by the auditory (Bell) and visual (special color) stimulus;
Command mode is the best menu and keyboard commands, for the user to choose. Input and output points: 512 points.
Input / output data points: 512 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:0.20.
Optical data communication line.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the user application can store the number of indicators A64BTL Manual.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words A64BTL Manual. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Related products
MITSUBISHI
Analog output module
A64DAIC
MITSUBISHI Analog output module A64DAIC
4 channels. Input resolution: -4000 4000,
MITSUBISHI
Analog output module
A64DAVC
MITSUBISHI Analog output module A64DAVC
4 channels. Input: DC0 20mA. Output resolu
MITSUBISHI
Temperature input module (RTD)
A64RD4C
MITSUBISHI Temperature input module (RTD) A64RD4C
4 channels. 4 wire type. Platinum resistance