Brand: MITSUBISHI
Name: Positioning module
Model: LD75P1-CM
Open collector output.
Axis of control: 1.
Maximum output pulse: pulse/s 200k.
Location data: 600 data / axis.
Max link distance: 2m.
With the parameter setting, the synchronization control can be easily realized. Do not need to write complex procedures.
Start / stop with synchronous control of the shaft.
Synchronous control of the axis and the positioning of the axis can coexist.
Through the clutch, the movement of the main shaft can be transferred to the output shaft.
Simple implementation of synchronization control.
Cam control is more simple
Cam data can easily create a variety of patterns.
Can be simple to achieve the gear, shaft, transmission, cam and other mechanical mechanisms to replace the software synchronization control.
It is not subject to the limitation of the concept of the electronic cam control so far, and can use the cam with high degree of freedom.
The stroke, speed, acceleration and beat can be confirmed on the graph, and the setting is carried out at the same time.
Can also be through the cam data thumbnail display, easy to confirm the cam data has been created.
Can import and export the cam data in CSV format.

CC-Link master / local station.
Transmission speed: 10Mbps.
Remote input / output: 8192 points.
Remote register: 2048 words.
Link points in Ver.2.0 CC-Link master station.
Using CC-Link to connect with multiple devices.
Rich device using open network CC-Link,
System can be constructed according to the control requirements MITSUBISHI LD75P1-CM.
Support Ver.2.0 CC-Link,
So it can be effectively used in the field of large capacity data communication LD75P1-CM
No need to set the transmission speed of the local station
Automatic tracking function of transmission speed
When used as a local station, the transmission speed of the master station can be automatically tracked,
Do not need to set up in the local station.
The transmission speed of the operation can be confirmed by the positive LED of the module MITSUBISHI LD75P1-CM. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Output points: 16 points.
Output form: bidirectional thyristor output.
Rated output voltage: AC100 ~ 240V.
Max load current: 0.6A/1 point.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: output 16 points) MITSUBISHI LD75P1-CM.
External wiring connection: 18 point terminal.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged MITSUBISHI Transistor output module (source).
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged MITSUBISHI Transistor output module (source).
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isolation.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convenient and flexible MITSUBISHI Transistor output module (source).
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability. Convert connectors to e-CON.Output channel number: 4ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 20 s/ch.
Resolution: 1/20000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth continuous aanalog output LD75P1-CM.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period MITSUBISHI LD75P1-CM.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.