LK Automation Limited
Home >> Price >> OMRON >> F3SJ-A0497N14 OMRON F3SJ-A0497N14
Brand sort

F3SJ-A0497N14 OMRON F3SJ-A0497N14

No PHOTO
Country: JAPAN
Name:
Market price: U.S.$ 0
(The following are the market open price not sales price!)
OMRON F3SJ-A0497N14
Cable Specifications: Fire-retardant, Robot cable.
No. of connector poles: 4.
Cable connection direction: Straight.
No. of cable cores: 2.
Cable outer diameter: 6.0 mm dia.
Cable core cross-sectional area: 0.5 mm.
Cable length: 1 m.
DC: Model.
Minimum order: 10.
UL-listed: Yes.
Water- and Environment-resistive FA OMRON F3SJ-A0497N14.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating F3SJ-A0497N14
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available OMRON F3SJ-A0497N14.
Three types of Connector Assembly: Crimping, soldering, and screw-on .
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Terminal type: Exposed-lead Models.
Protective tubing diameter D: 4.8 dia.
Protective tubing length L: 50cm.
Lead wire type: Standard.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperature Sensors OMRON F3SJ-A0497N14.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work .
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermoostat
(automatic // manual, RUN/STOP, alarm), interactive display PV/SV F3SJ-A0497N14.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation F3SJ-A0497N14.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
F3SJ-A0497N14 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=F3SJ-A0497N14&select=5


...more relevant model market price >>>>
Related products
OMRON
Safety Light Curtain
F3SJ-A0263N14
OMRON Safety Light Curtain F3SJ-A0263N14
Numer of eams: 28. Protective height:
OMRON
Safety Light Curtain
F3SJ-A0983N14
OMRON Safety Light Curtain F3SJ-A0983N14
Numer of eams: 108. Protective height
OMRON
Safety Light Curtain
F3SJ-A0270P55
OMRON Safety Light Curtain F3SJ-A0270P55
Numer of eams: 6. Protective height:
OMRON
Safety Light Curtain
F3SJ-A0695P14
OMRON Safety Light Curtain F3SJ-A0695P14
Numer of eams: 76. Protective height: