MITSUBISHI GT15-75QBUS2L
Output points: 24 points.
Voltage: AC100 ~ 240V.
OFF leakage current: 0.1mA.
Output type: bidirectional thyristor output.
Response time: 0.5Hz+1ms.
36 point terminal station.
With short circuit protection.
With the surge absorber.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor GT15-75QBUS2L
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal GT15-75QBUS2L.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc . .
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian GT15-75QBUS2L.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process .
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points. Power: 22kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option iis installed in the FR-A820-003800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity MITSUBISHI GT15-75QBUS2L.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motorr ppower used to select the DC reactor MITSUBISHI GT15-75QBUS2L.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.)
GT15-75QBUS2L Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=GT15-75QBUS2L&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Resist film
GT15-70PSGW
MITSUBISHI Resist film GT15-70PSGW
Protective film for 10.4 inch screen. Sc
MITSUBISHI
Resist film
GT15-70PSGB
MITSUBISHI Resist film GT15-70PSGB
Protective film for 10.4 inch screen. Sc
MITSUBISHI
Bus connection unit
GT15-75ABUS2L
MITSUBISHI Bus connection unit GT15-75ABUS2L
For the QnA/ACPU/ controller CPU A Seri
MITSUBISHI
Enclosure
GT15-70ATT-98
MITSUBISHI Enclosure GT15-70ATT-98
"Accessories for 10.4 inch models. Appli