LK Automation Limited
Home >> Price >> OMRON >> OMRON 70152-1701 SGEY-365-0-2000 100 70152-1701 SGEY-365-0-2000 100
Brand sort

OMRON 70152-1701 SGEY-365-0-2000 100 70152-1701 SGEY-365-0-2000 100

No PHOTO
Country: JAPAN
Name:
Market price: U.S.$ 0
(The following are the market open price not sales price!)
OMRON 70152-1701 SGEY-365-0-2000 100
Size: M8(Stainless steel)(See note 2.); Single; Shielded.
Sensing distance: 1.5 mm.
Connecting method (See note 1.): Pre-wired.
Body length: Long.
Output configuration: NPN.
Operation mode NO.
A new generation in global applications. Type of drive rod: one-way action roller type (vertical motion) OMRON 70152-1701 SGEY-365-0-2000 100.
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (1NC).
Safety limit switch in accordance with global standard EN 50047 70152-1701 SGEY-365-0-2000 100
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC) OMRON 70152-1701 SGEY-365-0-2000 100.
Forced open action structure.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm .
Elevator and escalator can be used. Output: SPDT.
Lighting: LED.
Operating voltage: 12 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with OMRON 70152-1701 SGEY-365-0-2000 100.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch .
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, E5GN-R03TC-FLK;
Resistance thermometer input, E5GN-R03P-FLK.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displayinng the status of the Temperature Coontroller (auto/
manual, RUN/STOP, and alarms) and the PV or SV 70152-1701 SGEY-365-0-2000 100.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs 70152-1701 SGEY-365-0-2000 100.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
70152-1701 SGEY-365-0-2000 100 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=70152-1701 SGEY-365-0-2000 100&select=5


...more relevant model market price >>>>
Related products
Related download