LK Automation Limited
Home >> Price >> OMRON >> OMRON XG8W-3044 XG8W-3044
Brand sort

OMRON XG8W-3044 XG8W-3044

No PHOTO
Country: JAPAN
Name:
Model: XG8W-3044
Price: 0
next one: OMRON XG8W-3041
Last one: OMRON XG8W-3431
OMRON XG8W-3044
Contact form: SPST-NO.
Type: Models with Test Button.
Rated voltage: AC: 24, 100, 110, 120, 200, 220, 230, 240;
DC: 12, 24, 48, 110, 220.
MK-S-series Relays with DC-switching,
Models That Can Switch 220 VDC, 10 A,
(Resistive Load).
Switch a DC load of 220 VDC, 10 A (resistive load).
Models for AC Loads can switch 250 VAC, 15 A (resistive load) OMRON XG8W-3044.
Lineup includes models with SPST-NO and SPST-NO/SPST,
NC contact forms XG8W-3044
Using a SPST-NO/SPST-NC contact form enables detecting,
contact welding. (When the NO contacts become welded, the,
NC contacts will maintain a minimum distance of 0.5 mm.).
Models available with operation indicators and built-in test buttons OMRON XG8W-3044.
RoHS compliant.
Standards: UL, IEC (TÜV certification) . Type of input: AC current input.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with OMRON XG8W-3044.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table .
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviInput terminals: M3 terminals.
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 1 output (Heater Burnout Detection,
SSR Short-circuit Failure Detection, Common).
Applicable load (See note.): 2 to 35 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects thhe burnout of 3-phase heaters XG8W-3044.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinaals (detachable), or compact slotted,
screw terminals (detachable) XG8W-3044.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.
XG8W-3044 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=XG8W-3044&select=5


...more relevant model market price >>>>
Related products
Related download