Cable length L: A, 2.0 m; B, 1.75 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Modular panel direct mounting type, easy to install and maintain the basic type.
The relay unit is modular and easy to maintain.
With LED action display function, so that the state of action at a glance OMRON S8JX-G01524C.
Tropical treatment and high temperature
S8JX-G01524C
Stable detection can be achieved with high ambient temperature.
Relay unit.
Product Name: 61F-11_ unit * 1.
Purpose: long distance use (2km). Appearance: Horizontal type.
Sensing method: Convergent reflective type OMRON S8JX-G01524C.
Sensing distance: 2 to 5 mm.
Output type: NPN output.
Output configuration: Dark-ON .
Accurately detects objects placed in,
front of shiny Background.
A shiny background can be used as long as the distance between,
the sensor and the background is 20 mm or more.
Detects minute objects such as a 0.05-mm-dia. pure copper wire.
Small dispersion in sensing distance.
Light modulation effectively reduces external light interference OMRON S8JX-G01524C.
Wide operating voltage range: 5 to 24 VDC . Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 2 loops,
heater burnout detection function;
Temperature sensor inputs: Thermocouple,
input (R, S, K, J, T, B, L);
Control outputs: Open collector,
NPN outputs (pulses).
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output. Type: 1a1b welding terminal.
Shape: round.
Type: small load.
Action: instantaneous action (auto recovery).
With light: LED with light.
Using voltage: DC12V.
Operation Department color: green.
20mm long, with 12 round series
High brightness all one side light.
Because it is round, so easy to punch.
Miniaturization, operation feel good. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 4.8 dia.
Protective tubing length L: 50 cm.
Lead wire type: Standard.
Lead wire length M: 8m.
A Wide Variety of High-prrecision .
Tempeerature Sensors S8JX-G01524C.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teempperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal S8JX-G01524C.
S8JX-G01524C Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=S8JX-G01524C&select=5