LK Automation Limited
Home >> Supply >> C200H-AD002 Analog Input Module OMRON C200H-AD002 Current input: 4 to 20 mA
Search
Information sort

C200H-AD002 Analog Input Module OMRON C200H-AD002 Current input: 4 to 20 mA


Model: CPM2C-10C1DR-D. CPU Unit: Units with 10 I/O points.
I/O terminal block.
Inputs: 6 inputs.
Outputs: 4 outputs.
Input type: 24 VDC.
Output type: relay.
Internal clock: Yes.UM: 15.2K words.
DM: 6K words.
EM: 6K words.
Instruction processing time (basic instructions): 0 C200H-AD002.15 micro.s min.
No. of I/O points: 1, 184 points.
Max. no.of con-necting Expansion I/O Racks: 3 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max C200H-AD002. no. of con-necting Special I/O Units: 10.
RS-232C: NO.
Model: C200H-AD002.
Input points: 8.
Voltage input: 1 to 5 V, 0 to 10 V, or –10 to 10 V.
Current input: 4 to 20 mA.Name: Two-tier Screw Terminal Block.
Specifications: Inputs; 16 inputs; PNP.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet C200H-AD002.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON C200H-AD002.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. 80 cm for CP1W/CPM1A Expansion UnitsSpecification: 32 output points OMRON C200H-AD002.Model: C200H-OD218.
No. of points: 32 pts.
Specifications: nit 4.5 VDC, 16 mA to 26.4 VDC, 100 mA. .
Weight: 180g max.C500-OC I/O Unit Transistor Output 16 pts C500-OC221(3G2A5-OC221).
AC250/DC24V 2A.UM: 3.2K words.
DM: 4K words OMRON C200H-AD002.
EM: --.
Instruction processing time (basic instructions): 0.3 µ.s min.
No. of I/O points: 640 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Unit type: CJ1 Basic I/O Units.
Product name: DC Input/Transistor Output Units.
Specifications: Output type, Sourcing;
I/O points, 16 inputs, 16 outputs;
Input voltage,Input current, 24VDC, 7mA,
24VDC, 0.5A Short-circuit protection;
Commons, 16 points, 1 common;
External connection, MIL connector.
No. of words allocated: 4 words.
Current consumption: 5V, 0.13A; 24V, --.
Standards: UC1, N, L, CE. A Wide Range of Basic Mixed,
I/O Units for Different Applications,
and Wiring Methods C200H-AD002.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems.

Related supply information