LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> OMRON S3200-CN202-62-62 Macro Reference Safety Light Curtain Manual

OMRON S3200-CN202-62-62 Macro Reference Safety Light Curtain Manual

Product model: S3200-CN202-62-62
Name: Safety Light Curtain
Brand: OMRON
Sort: Macro Reference
File language: English
File size: 6.89MB
Type: open type.
Structure: DIN guide rail mounting type.
Capacity: 100W.
Output voltage: 12V.
Output current: 8.5A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function S3200-CN202-62-62 Manual.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity S3200-CN202-62-62
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock S3200-CN202-62-62 Manual.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Category: incidental cover type S3200-CN202-62-62 Manual.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 50W.
Output voltage: 5V.
Output current: 10A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device OMRON Safety Light Curtain Manual.
Built in support for determining the abnormal causes of the new under voltage detection function OMRON Safety Light Curtain Manual.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage OMRON Safety Light Curtain Manual.
(except for the 300/600/1500W output terminals)
Support fiinger touch protection to prevent electric shock S3200-CN202-62-62 Macro Reference.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whhen the fan is replaced by the customer S3200-CN202-62-62 Manual. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)"
Related products