LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> OMRON OMRON K3HB-HTA-DRT1 Communications Manual K3HB-HTA-DRT1

OMRON OMRON K3HB-HTA-DRT1 Communications Manual K3HB-HTA-DRT1

Product model: K3HB-HTA-DRT1
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
File size: 2.07MB
Measuring voltage: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC.
Supply voltage: 200-230 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervoltages K3HB-HTA-DRT1 .
Manual resetting and automatically resetting supported by one Relay K3HB-HTA-DRT1
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Input type: DC current input K3HB-HTA-DRT1 .
Output type: relay contact; 1c HH; PASS, H, L, LL: each 1a.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-HTA-DRT1 .
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type. Model: DGR-H (67G).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries.
Unitt with 2 relay elements K3HB-HTA-DRT1 Communications Manual.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determiine the direction of the sudden drop in the voltage to 0 of the short-circuit accident K3HB-HTA-DRT1 Communications Manual.
2 stage cross terminal stand with cover with convenient wiring.
Related products
OMRON
Temperature panel
K3HB-HTA-CPAC11 AC/DC24
OMRON Temperature panel K3HB-HTA-CPAC11 AC/DC24
Type of input: platinum resistance / thermoco
OMRON
Voltage and current panel meter
K3HB-XVA-DRT1 AC100-240
OMRON Voltage and current panel meter K3HB-XVA-DRT1 AC100-240
Type of input: AC voltage input. Output type
OMRON
Voltage and current panel meter
K3HB-XAA-DRT1 AC100-240
OMRON Voltage and current panel meter K3HB-XAA-DRT1 AC100-240
Type of input: AC current input. Output type