Product model: K3HB-PPB-A1
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
File size: 1.85MB
Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
DeviceNet; DeviceNet:--.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-PPB-A1 K3HB-PPB-A1
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identificationType of input: platinum resistance / thermocouple input K3HB-PPB-A1 .
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
Transistor: -; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Temperature indicator and measurement of various processes.
Action determine the color, can switch the green / Red 2 kinds of color display.
High speed sampling of 50 /s (20ms) K3HB-PPB-A1 .
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
The temperature input compensation can be easily set by 2 points.
DTime specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the starrt of operation K3HB-PPB-A1 Communications Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-PPB-A1 Communications Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Voltage and current panel meter
K3HB-XAA-FLK1AT11 AC100-240
OMRON Voltage and current panel meter K3HB-XAA-FLK1AT11 AC100-240
Type of input: AC current input. Output type
OMRON
Rotating pulse meter
K3HB-RNB-CPAC11 AC/DC24V
OMRON Rotating pulse meter K3HB-RNB-CPAC11 AC/DC24V
Input type: NPN/ voltage pulse input type. E
OMRON
Load sensor, mV instrument
K3HB-VLC-CPEC11 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-CPEC11 AC/DC24
Category: external supply 100mA DC5V type. I