LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> OMRON GX-MD1612 Manual GX-MD1612 PROGRAMMING MANUAL

OMRON GX-MD1612 Manual GX-MD1612 PROGRAMMING MANUAL

Product model: GX-MD1612
Name: DeviceNet Slaves
Brand: OMRON
Sort: PROGRAMMING MANUAL
File language: English
File size: 9.25MB
Safety outputs *3: Instantaneous, 2(Semiconductor);
OFF-delayed*2, 2 (Semiconductor).
Auxiliary outputs *4: 2(Semiconductor).
Logical AND connection: Inputs, 2(Semiconductor); Outputs, 2(Semiconductor).
No. of input channels: 1 or 2 channels.
Max. OFF-delay time *1: 150 s.
Rated voltage: 24 VDC GX-MD1612 PROGRAMMING MANUAL.
Terminal block type: Screw terminals.
Logical AND Function Adds Flexibility to I/O Expansion GX-MD1612
Facilitates partial or complete control system setup.
Solid-state outputs (excluding Expansion Units).
Detailed LED indications enable easy diagnosis.
TÜV SÜD certification for compliance,
with IEC/EN61508 (SIL3), EN ISO13849-1 (PLe/Safety Category 4).
Approved by UL and CSA.
New unit joins the Series with the following two additional features:
-OFF-delay time of up to 150 seconds can be set GX-MD1612 PROGRAMMING MANUAL.
-Two logical AND connection inputs. Input terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note GX-MD1612 PROGRAMMING MANUAL. ): 2 to 25 A, 200 to 480 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Screw mounting.
Applicable load: 15 A, 100 to 240 VAC.
Number of pole: 2.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliantt GX-MD1612 Manual.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIIN Track mounting types mount to DIN Track GX-MD1612 Manual.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification).
Related products
OMRON
EtherCAT Remote I/O Terminals
GX-MD1611
OMRON EtherCAT Remote I/O Terminals GX-MD1611
Internal I/O common: NPN. I/O indicators: LE
OMRON
Digital I/O Terminal 3-tier Terminal Block Type
GX-MD1618
OMRON Digital I/O Terminal 3-tier Terminal Block Type GX-MD1618
Internal I/O common: NPN. I/O indicators: LE
OMRON
Digital I/O Terminal 3-tier Terminal Block Type
GX-OD1612
OMRON Digital I/O Terminal 3-tier Terminal Block Type GX-OD1612
Input capacity: 16 points. Rated current ON
OMRON
Digital I/O Terminal 3-tier Terminal Block Type
GX-MD1612
OMRON Digital I/O Terminal 3-tier Terminal Block Type GX-MD1612
Internal I/O common: NPN. I/O indicators: LE