Product model: E5CN-HQQ2HHD
Name: OMRON E5CN-HQQ2HHD Manual E5CN-HQQ2HHD Basic Type Basic Type
Brand: OMRON
Sort: Basic Type Basic Type
File language: English
File size: 6.14MB
Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or resistance thermometer.
Auxiliary outputs: None.
Control output 1: Relay output.
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function E5CN-HQQ2HHD Basic Type".
Indication Accuracy.
Thermocouple input: ±0 E5CN-HQQ2HHD3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5CN-HQQ2HHD Basic Type".
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard.
No. of auxiliary outputs: --.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No E5CN-HQQ2HHD Basic Type". of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-QTC;
Resistance thermometer input, E5GN-QP.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUNN/STOP, and alarms) and the PV or SV E5CN-HQQ2HHD Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thhermo version 4 E5CN-HQQ2HHD Manual. 2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. 0.5M E3Z-L61-ECON fine beam
Reflective type
Related products
OMRON
Programmed temperature controller
E5CN-HTR2BF
OMRON Programmed temperature controller E5CN-HTR2BF
Size: 48 48mm, terminal type. Category: con
OMRON
High performance temperature controller
E5CN-HV2BFD
OMRON High performance temperature controller E5CN-HV2BFD
Size: 48 x 48mm. Body: terminal type. Type: c
OMRON
Programmed temperature controller
E5CN-HTQQ2B
OMRON Programmed temperature controller E5CN-HTQQ2B
Size: 48 48mm, terminal type. Category: con
OMRON
Programmed temperature controller
E5CN-HTC2BD
OMRON Programmed temperature controller E5CN-HTC2BD
Size: 48 48mm, terminal type. Type: control