Product model: K3HB-XAA-L2AT11 AC100-240
Name: Voltage and current panel meter
Brand: OMRON
Sort: PDF datasheet
File language: English
File size: 1.90MB
Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
Transistor: -; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Temperature indicator and measurement of various processes K3HB-XAA-L2AT11 AC100-240 PDF datasheet.
Action determine the color, can switch the green / Red 2 kinds of color display K3HB-XAA-L2AT11 AC100-240
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
The temperature input compensation can be easily set by 2 points.
DPower supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control K3HB-XAA-L2AT11 AC100-240 PDF datasheet.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload K3HB-XAA-L2AT11 AC100-240 PDF datasheet.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cycclic control K3HB-XAA-L2AT11 AC100-240 PDF catalog.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-XAA-L2AT11 AC100-240 PDF catalog.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Rotating pulse meter
K3HB-RNB-FLK3AT11 AC100-240
OMRON Rotating pulse meter K3HB-RNB-FLK3AT11 AC100-240
Input type: NPN/ voltage pulse input type. E
OMRON
Time interval table
K3HB-PPB-FLK1AT11 AC100-240
OMRON Time interval table K3HB-PPB-FLK1AT11 AC100-240
Input type: PNP input type. Event input term
OMRON
Rotating pulse meter
K3HB-RNB-L1AT11 AC100-240
OMRON Rotating pulse meter K3HB-RNB-L1AT11 AC100-240
Input type: NPN/ voltage pulse input type. E
OMRON
Load sensor, mV instrument
K3HB-VLC-L1ET11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-L1ET11 AC100-240
Category: external supply 100mA DC5V type. I