LK Automation Limited
Home >> Download >> OMRON >> Catalog Download >> OMRON E3X-DAB8-S PDF datasheet E3X-DAB8-S datasheet PDF catalog

OMRON E3X-DAB8-S PDF datasheet E3X-DAB8-S datasheet PDF catalog

Product model: E3X-DAB8-S
Name: Digital Fiber Amplifier Unit
Brand: OMRON
Sort: PDF datasheet
File language: English
File size: 1.55MB
Appearance: Shielded, M12.
Sensing distance: 3 mm.
Output configuration: DC 2-wire.
Operation mode: NO.
Spatter-resistant Fluororesin,
coated Proximity Sensor.
Superior spatter resistance.
Long Sensing-distance Models added for sensing,
distances up to 15 mm.
Pre-wired Smartclick Connector Models are also available E3X-DAB8-S PDF datasheet. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black E3X-DAB8-S
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input E3X-DAB8-S PDF datasheet.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors E3X-DAB8-S PDF datasheet.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Size: M12 (Brass); Single; Unshielded.
Sensing distance: 5 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. Sensor type: Transparent detected with P-opaquing function.
Sensing distance: 100 to 500 mm with E39-RP1.
Connection method: M12 connecctor E3X-DAB8-S PDF catalog.
Model: PNP output.
A new generation in sensing performance.
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered.
A wide variety of models.
Models designed forr special applications E3X-DAB8-S PDF catalog.
Non-stop detection.
High quality and reliability.
High EMC protection.
High light immunity.
Robust and waterproof housing.
Related products
OMRON
Digital Fiber Amplifier
E3X-DA21-N 2M
OMRON Digital Fiber Amplifier E3X-DA21-N 2M
Type: Monitor-output models. Control output:
OMRON
Digital Fiber Amplifier Unit
E3X-DA7R-S
OMRON Digital Fiber Amplifier Unit E3X-DA7R-S
Type: Ultra-long-term APC models. Connecting
OMRON
Digital Fiber Amplifier
E3X-DA41-N 2M
OMRON Digital Fiber Amplifier E3X-DA41-N 2M
Type: Standard models. Control output: ON/OF