Product model: L60MD4-G-CM
Name: Multiple input (voltage / current / temperature) module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
File size: 12.21MB
Error output.
Rated open and close voltage, current: DC24V, 0.5A.
Minimum open and close load: DC5V, 1mA.
Response time (OFF, ON): 10ms below.
Response time (ON, OFF): 12ms below.
Life (Mechanical): more than 20 million times.
Life (Electrical) rated open and close voltage, current more than 100 thousand times L60MD4-G-CM PDF catalog .
Suitable for wire specifications: 0.3 ~ 2 square mm (AWG22 ~ 14) (twisted pair / single line) L60MD4-G-CM
External wiring connection mode: spring clip terminal.
DC5V internal consumption current: 0.06A.
Weight: 0.11kg. Open collector output.
Axis of control: 1.
Maximum output pulse: pulse/s 200k.
Location data: 600 data / axis.
Max link distance: 2m.
With the parameter setting, the synchronization control can be easily realized L60MD4-G-CM PDF catalog . Do not need to write complex procedures.
Start / stop with synchronous control of the shaft.
Synchronous control of the axis and the positioning of the axis can coexist.
Through the clutch, the movement of the main shaft can be transferred to the output shaft.
Simple implementation of synchronization control.
Cam control is more simple
Cam data can easily create a variety of patterns L60MD4-G-CM PDF catalog .
Can be simple to achieve the gear, shaft, transmission, cam and other mechanical mechanisms to replace the software synchronization control.
It is not subject to the limitation of the concept of the electronic cam control so far, and can use the cam with high degree of freedom MITSUBISHI L60MD4-G-CM PDF datasheet.
The stroke, speed, acceleration and beat can be confirmed on the graph, and the setting is carried out at the same time MITSUBISHI L60MD4-G-CM PDF datasheet.
Can also be through the cam data thumbnail display, easy to confirm the cam data has been created.
Can import and export the cam data in CSV format. "Universal output function: source type.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns MITSUBISHI L60MD4-G-CM PDF datasheet.
Communication interface: USB/Ethernet (built-in CC-Link function).
Program capacity: 20K step.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programminng tool L60MD4-G-CM datasheet.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurrement L60MD4-G-CM PDF catalog .
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ". "