Product model: FX2NC-232ADP
Name: RS-232C adapter
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
File size: 50.49MB
MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 3.7KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) MITSUBISHI FX2NC-232ADP PDF catalog FX2NC-232ADP
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load MITSUBISHI FX2NC-232ADP PDF catalog. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 18.5KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) MITSUBISHI FX2NC-232ADP PDF catalog.
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 280kw.
SLD converter rated current: 610A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup.
No need to adjust the parameters (plus deceleration time or torque, etc.), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteristic drive motoor FX2NC-232ADP PDF datasheet.
In the state of the sensor can not only drive the high efficiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor).
Othher manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving FX2NC-232ADP PDF datasheet.
Related products
MITSUBISHI
Extension module
FX2NC-16EX-DS
MITSUBISHI Extension module FX2NC-16EX-DS
Input points: 16 points. Power supply: the a
MITSUBISHI
Pulse output module
FX2N-1PG-E
MITSUBISHI Pulse output module FX2N-1PG-E
Axis of control: 1. Applicale PLC:FX1N, FX2N
MITSUBISHI
Conversion adapter
FX2NC-CNV-IF
MITSUBISHI Conversion adapter FX2NC-CNV-IF
In FX1NC, FX2NC, PLC FX3U connection FX0N, FX
MITSUBISHI
PLC
FX2NC-64MT-D/UL
MITSUBISHI PLC FX2NC-64MT-D/UL
Max input / output points: 64 points. Power s