Product model: A7GT-J71AT23B
Name: Data connection unit
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
File size: 6.39MB
CPU connection program input device.
ACPU use. Output points: 32 points.
Voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
32 points / a common end.
38 point terminal station.
With heat protection.
With short circuit protection.
With the surge absorber MITSUBISHI Data connection unit PDF datasheet.
Each scanning process. Focus on the input signal sampling A7GT-J71AT23B Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh MITSUBISHI Data connection unit PDF datasheet.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay MITSUBISHI Data connection unit PDF datasheet.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive A7GT-J71AT23B PDF datasheet.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference A7GT-J71AT23B PDF datasheet. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation A7GT-J71AT23B PDF datasheet.
Read only memory. Manufacturers use, content can not be changed, power does not disappear. For A6TBXY36/A6TBXY54/A6TBX70E (common cathode; drain type) long 3m.Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 16 points.
Output voltage: DC24V/AC240V, 2A/1 point, 4A/ common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public side.
50 point terminal station.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan faault signal A7GT-J71AT23B PDF catalog.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points MITSUBISHI Data connection unit PDF datasheet.
Related products
MITSUBISHI
Data connection unit
A7GT-J71AR23
MITSUBISHI Data connection unit A7GT-J71AR23
MELSECNET II. Coaxial circuit.
MITSUBISHI
Network connection unit
A7GT-J71BR13
MITSUBISHI Network connection unit A7GT-J71BR13
MELSECNET/10. Inter-PC coaxial us.
MITSUBISHI
Data connection unit
A7GT-J71AP23
MITSUBISHI Data connection unit A7GT-J71AP23
MELSECNET II. Optical fier loop.