LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> pull-reset safety limit switch D4N-9A62R INSTRUCTION sheet OMRON D4N-9A62R Manual

pull-reset safety limit switch D4N-9A62R INSTRUCTION sheet OMRON D4N-9A62R Manual

Product model: D4N-9A62R
Name: pull-reset safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.54MB
Head material: Plastic*1.
Release key position: Bottom.
Release key type: Special release key(resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 3NC+2NC D4N-9A62R INSTRUCTION sheet D4N-9A62R
Conduit opening: Pg13.5.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum D4N-9A62R INSTRUCTION sheet.
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available. Actuator: Plunger.
Conduit openings: G1/2 (PF1/2).
2NC (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification D4N-9A62R INSTRUCTION sheet.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever OMRON D4N-9A62R Manual.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion OMRON D4N-9A62R Manual.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13).
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Release Key Type: Special (resin) OMRON D4N-9A62R Manual.
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @.
Conduit size (See Note.): G1/2.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion pointt D4N-9A62R .
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4N-9A62R INSTRUCTION sheet.
The plastic material makes the Slide Key suitable,
for lightweight doors.
Related products
OMRON
Pull-reset Safety Limit Switch
D4N-4C31R
OMRON Pull-reset Safety Limit Switch D4N-4C31R
Actuator: Plunger. Conduit size: 1-conduit
OMRON
Pull-reset Safety Limit Switch
D4N-4D20R
OMRON Pull-reset Safety Limit Switch D4N-4D20R
Actuator: Roller lever resin lever, resin ro
OMRON
Safety Limit Switch
D4N-8D20
OMRON Safety Limit Switch D4N-8D20
Actuator: Roller lever resin lever, resin ro
OMRON
Pull-reset Safety Limit Switch
D4N-8D31R
OMRON Pull-reset Safety Limit Switch D4N-8D31R
Actuator: Plunger. Conduit size: 2-conduit