Product model: E3ZM-T88H
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 22.48MB
E3JK-5M2 detection methods: the firing pattern,
Connection mode: lead wire,
Detection range: 5m.
Output status: shading ON.
Output: relay,
2 types of cost reductionCase color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: -- E3ZM-T88H Manual.
No. of event inputs: -- E3ZM-T88H
Transfer output *2: Transfer output using control output.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function E3ZM-T88H Manual.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E3ZM-T88H Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4 OMRON E3ZM-T88H INSTRUCTION sheet. 2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Size: 48 x 96mm.
Ontology: terminal type, temperature input type OMRON E3ZM-T88H INSTRUCTION sheet.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function OMRON E3ZM-T88H INSTRUCTION sheet.
Event input points: -.
Transfer output: -.
Communication: RS-232C.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E3ZM-T88H .
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E3ZM-T88H Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
Related products
OMRON
Compact Photoelectric Sensor
E3ZM-LS67H
OMRON Compact Photoelectric Sensor  E3ZM-LS67H
Sensing method: BGS reflective fixed distanc
OMRON
Compact Photoelectric Sensor
E3ZM-LS66H
OMRON Compact Photoelectric Sensor  E3ZM-LS66H
Sensing method: BGS reflective fixed distanc
OMRON
Compact Photoelectric Sensor
E3ZM-LS86H
OMRON Compact Photoelectric Sensor  E3ZM-LS86H
Sensing method: BGS reflective fixed distanc
OMRON
Compact Photoelectric Sensor
E3ZM-D82
OMRON Compact Photoelectric Sensor  E3ZM-D82
Sensing method: Diffuse reflective. Connecti