LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> photoelectric sensors E3S-AD42 Manual OMRON E3S-AD42 INSTRUCTION sheet

photoelectric sensors E3S-AD42 Manual OMRON E3S-AD42 INSTRUCTION sheet

Product model: E3S-AD42
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.24MB
Output configuration: DC switching NPN (normally open or closed selectable).
Sensing method: Reflective; Convergent reflective (Zone setting).
Sensing distance: 20 to 70 cm Sensing zone.
Capable of Setting the Sensing Range.
Using an Ultrasonic Beam.
Ensures the stable detection of a variety of objects,
regardless of the color, transparency, or material E3S-AD42 Manual.
(metallic or non-metallic) of the objects E3S-AD42
Limits the ultrasonic beam width to 8°, thus,
detecting minute objects as small as 2 x 2 cm.
Detects objects smoothly while largely suppressing,
interference from background objects.
Sealed to resist dust and dirt and emits ultrasonic,
waves at a frequency of approximately 200 kHz,
thus providing high immunity from impact and,
environmental noise E3S-AD42 Manual. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1 dia.
Protective tubing length L: 20 cm.
Lead wire type: Standard.
Lead wire length M: 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E3S-AD42 Manual.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Appearance: Shielded, M12 OMRON E3S-AD42 INSTRUCTION sheet.
Sensing distance: 4 mm.
Output: PNP.
Model: Operation mode NO.
Aluminum and Iron Both.
Detectable from Long Distances OMRON E3S-AD42 INSTRUCTION sheet. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function OMRON E3S-AD42 INSTRUCTION sheet.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermmo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E3S-AD42 .
Through the infrared port can be carried out from the frront of the communication E3S-AD42 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products
OMRON
Transparent Object Detection Sensor
E3S-R31
OMRON Transparent Object Detection Sensor E3S-R31
Sensing method: Retro reflective. Appearance
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AD13
OMRON Built-in Amplifier Photoelectric Sensor E3S-AD13
Sensing method: Diffuse-reflective Sensors.
OMRON
Amplifier built-in type photoelectric switch
E3S-BT81
OMRON Amplifier built-in type photoelectric switch E3S-BT81
Small, easy to use. Detection mode: on the ra
OMRON
PCB Sensors
E3S-LS3N
OMRON PCB Sensors E3S-LS3N
Sensing method: Convergent reflective. Conn