LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> guard lock safety-door switch D4SL-N2CFG-N INSTRUCTION sheet OMRON D4SL-N2CFG-N Manual

guard lock safety-door switch D4SL-N2CFG-N INSTRUCTION sheet OMRON D4SL-N2CFG-N Manual

Product model: D4SL-N2CFG-N
Name: guard lock safety-door switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.57MB
Direction of Operation Key insertion: Horizontal.
Cable length: 1 m.
2NC (Slow-action).
Slim Safety Door Switches with IP67 Rating.
Slim design with a width of only 17 mm.
(three-contact models).
Reversible design allowing either front or rear mounting.
Built-in Switches with two- or three-terminal contact D4SL-N2CFG-N INSTRUCTION sheet.
construction are available.
Operation Key with rubber mounting hole to absorb vibration and shock D4SL-N2CFG-N
IP67 degree of protection. Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms D4SL-N2CFG-N INSTRUCTION sheet.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) D4SL-N2CFG-N INSTRUCTION sheet.
Certified standards: UL, EN (TÜV), and CCC. Type: M5.
Actuator: Wobble stick actuator; Short spring.
Cable length: 1 m.
Detects Objects in Multiple Directions,
with High Sensitivity, Ideal for Robotics,
Slow-action switching mechanism used OMRON D4SL-N2CFG-N Manual.
Gold-plated contact with coil spring capable of switching,
micro current/voltage load while providing high contact reliability OMRON D4SL-N2CFG-N Manual.
Inputs directly to microcomputers and programmable controllers.
Three sizes (M10, M8, and M5) and three types of compact actuators.
Easy panel mounting. Actuator: Adjustable rod lever.
Conduit openings: M20.
1NC/1NO (Snap-action).
Robust safety limit switch with metal housing OMRON D4SL-N2CFG-N Manual.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion D4SL-N2CFG-N .
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) D4SL-N2CFG-N INSTRUCTION sheet.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.