LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> OMRON E5EN-R3HMT-500 Manual E5EN-R3HMT-500 INSTRUCTION Manual

OMRON E5EN-R3HMT-500 Manual E5EN-R3HMT-500 INSTRUCTION Manual

Product model: E5EN-R3HMT-500
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
File size: 1.84MB
Size: M8(Stainless steel)(See note 2.); Single; Unshielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Long.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V) E5EN-R3HMT-500 INSTRUCTION Manual.
Shell color: black.
Control output: relay output E5EN-R3HMT-500
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: -.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved E5EN-R3HMT-500 INSTRUCTION Manual.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5EN-R3HMT-500 INSTRUCTION Manual.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Sensing method: Through-beam Sensors.
Appearance: Horizontal.
Connection method: Pre-wired.
Sensing distance: 7 m.
Functions: Timer Self Diagnosis Turbo External Diagnosis.
Model: PNP output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 4.8 dia.
Protective tubing length L: 35 cm.
Lead wire type: Heat resistive.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperaturee Sensors E5EN-R3HMT-500 Manual.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5EN-R3HMT-500 Manual.
Related products
OMRON
Foundation type temperature controller
E5EN-R3HT-N
OMRON Foundation type temperature controller E5EN-R3HT-N
Size: 48 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5EN-R3H03T-FLK-N
OMRON Foundation type temperature controller E5EN-R3H03T-FLK-N
Size: 48 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5EN-R3HL-N
OMRON Foundation type temperature controller E5EN-R3HL-N
Size: 48 x 96mm. Ontology: terminal type, ana
OMRON
Foundation type temperature controller
E5EN-R3PBT-N
OMRON Foundation type temperature controller E5EN-R3PBT-N
Size: 48 x 96mm. Ontology: terminal type, tem