LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> OMRON E5CS-Q1PU-W INSTRUCTION Manual

OMRON E5CS-Q1PU-W INSTRUCTION Manual

Product model: E5CS-Q1PU-W
Name: temperature controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
File size: 14.72MB
Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 3.2 dia.
Protective tubing length L: 50cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5CS-Q1PU-W .
Ideal for the thermal input devices of Temperature Controllers E5CS-Q1PU-W
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Sensing method: Through-beam.
Connection method: Pre-wired Connector (M8, 4 pins).
Sensing distance: 25 mm E5CS-Q1PU-W .
No. of opti- cal axes: 2.
Model: NPN output.
Photoelectric Sensor with Grooved.
Design and Easy Settings .
Groove-type Sensor with groove width of 25 mm.
Models are available with one or two light axes.
Models are available with M8 pre-wired connectors. Sensing method: Reflective model(for mark detection).
Connection method: Pre-wired (2 m).
Sensing distance: 35±5 mm.
Extremely thin beam ideal for detection of minute objects and marks E5CS-Q1PU-W .
Ideal for detection of small objects and slight color differences.
Bad mark detection.
Detection of thin wire of 200 μ.
Detection of slight level differences. Appearance: Standard.
Sensing method: Through-beam type (with slot).
Cable length: 2 m.
Sensing distance: 5 mm (slot width).
configuration Output: Light-ON.
Indicator mode: No incident light.
Model: NPN output.
Slim, Compact Photomicrosensor.
that is still easy to use.
Compact, thin profile enables dense mounting.
Indicator is visible from both sides.
Wide operating voltage range: 5 to 24 VDC. Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermosstat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5CS-Q1PU-W INSTRUCTION Manual.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E5CS-Q1PU-W INSTRUCTION Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products