LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> OMRON E2FM-X5D1-M1TGJ-T Manual E2FM-X5D1-M1TGJ-T INSTRUCTION sheet

OMRON E2FM-X5D1-M1TGJ-T Manual E2FM-X5D1-M1TGJ-T INSTRUCTION sheet

Product model: E2FM-X5D1-M1TGJ-T
Name: proximity switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 1.48MB
Size: 48 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2: relay output.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input E2FM-X5D1-M1TGJ-T INSTRUCTION sheet.
Heating wire break, SSR fault detection function: 1 points E2FM-X5D1-M1TGJ-T
Communication: RS-485.
Event input: 6 points.
Remote SP input: there.
Transfer output: have.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm E2FM-X5D1-M1TGJ-T INSTRUCTION sheet.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications E2FM-X5D1-M1TGJ-T INSTRUCTION sheet.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E2FM-X5D1-M1TGJ-T Manual.
Through the infrared port can be carried out from the frront of the communication E2FM-X5D1-M1TGJ-T Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.