LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> OMRON E2CY-V3A Manual E2CY-V3A INSTRUCTION sheet

OMRON E2CY-V3A Manual E2CY-V3A INSTRUCTION sheet

Product model: E2CY-V3A
Name: proximity sensor
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 2.09MB
Sensing range: 240 to 4,000 mm.
Now, more advanced with a new mutual.
interference prevention function.
Long-distance detection of up to 6,000 mm supports a wide vari,
ety of applications.
The Sensor is not affected by the color or material of objects.
A setting plug with temperature compensation makes it easy to,
set the sensing range E2CY-V3A INSTRUCTION sheet.
Mutual interference prevention E2CY-V3A
Detection methods: the firing pattern.
Detection range: 300mm.
Usage: slender type,
Small thin space probe;
Interference prevention function with close installationElement type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 15 dia.
Protective tubing length L: 50 cm.
A Wide Variety of High-precision E2CY-V3A INSTRUCTION sheet.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E2CY-V3A INSTRUCTION sheet. Appearance: Shielded, M12.
Sensing distance: 2 mm.
Output configuration: DC 2-wire, (3)-(4) pin arrangement.
Model: Operation mode, NO.
Chip-immune Inductive.
Proximity Sensor.
Correct operation even with aluminum or iron chips sticking,
to the Sensor.
Only the sensing object is detected.
Pre-wired Smartclick Connector Models also available. The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: current output.
Control mode: standard.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,

Further performance improvement E2CY-V3A Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E2CY-V3A Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products