Operation indicator: With operating indication; Standard load.
Ratings: 4 A at 30 VDC.
Actuator: Roller lever.
Cable length : 3m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4SL-N2QFG-D4N INSTRUCTION sheet. )
Sealing characteristics that meet IEC IP67 degree of protection D4SL-N2QFG-D4N
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers D4SL-N2QFG-D4N INSTRUCTION sheet.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.) Actuator: Top plunger.
Type: Limit.
Operation Indicator: Provided.
Repeat accuracy: 3 µm max.
Operating force OF max: 3.92 N.
Cable lead outlet: Lead outlet, Pre-wired; Length, 3 m D4SL-N2QFG-D4N INSTRUCTION sheet.
Degree of protection: IP67.
High-precision Switch for Detecting Micron-unit,
Displacement.
Ideal for detecting and measuring wear of cutting,
tools or for original point of work.
Ceramic plungers on M5, M8, and slim models for,
superior abrasion resistance and resistance to,
temperature changes.
Direct input possible to microprocessors and,
programmable controllers.
A version with screw-type cable connector available,
for easy installation and maintenance. Actuator: Roller lever (resin lever, resin roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available D4SL-N2QFG-D4N Manual. )
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used witth both standard loads and microloads D4SL-N2QFG-D4N Manual.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.