LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q173NCCPU Application User's Manual

MITSUBISHI Q173NCCPU Application User's Manual

Product model: Q173NCCPU
Name: PLC
Brand: MITSUBISHI
Sort: Application User's Manual
File language: English
File size: 5.56MB
8 slots.
Requires 1 power modules.
Used to install the old section of the large A series PLC module.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order Q173NCCPU Application.
So, sometimes also known as the order control Q173NCCPU
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read Q173NCCPU Application.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three Q173NCCPU Application.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.SI/QSI/H-PCF/ broadband H-PCF optical cable.
Double circuit.
Remote I/O network (remote I/O station).
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between sttations, the length of the total cable length, strong anti-interference Q173NCCPU User's Manual.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system Q173NCCPU User's Manual. ..... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.
Related products
MITSUBISHI
Manual pulse generator interface module
Q173DPX
MITSUBISHI Manual pulse generator interface module Q173DPX
Manual pulse generator /INC synchronous encod
MITSUBISHI
CPU unit
A2CCPU
MITSUBISHI CPU unit A2CCPU
Input and output points: 512 points. Input /
MITSUBISHI
Motion CPU module
Q173CPUN-T
MITSUBISHI Motion CPU module Q173CPUN-T
Control axis: maximum 32 axes. Teaching runni
MITSUBISHI
Motion controller
Q173DSCPU
MITSUBISHI Motion controller Q173DSCPU
Control axis: up to 32 axes. Servo amplifier