Product model: Q03UDCPU
Name: PLC
Brand: MITSUBISHI
Sort: Application User's Manual
File language: English
File size: 5.56MB
5 slots; requires 1 AnS series PLC power modules;
Used to install large AnS series PLC module.
Base plate of AnS series PLC.
QA1S series PLC 5 slot main substrate.
AnS series of modules can be installed. Output: 8 channels.
Input (resolution): 0~4000; -4000~4000; 0~12000; -12000~12000; -16000~16000.
Output: DC-10~10V Q03UDCPU User's Manual.
Conversion speed: 80 s/1 channel.
18 point terminal station Q03UDCPU
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.
The possibility of expanding control with intelligent function.
Providing a variety of analog modules, is the ideal choice for process control applications.
Can also meet the needs of high speed, high precision control Q03UDCPU User's Manual.
Most suitable analog modules for high speed conversion control.
Can provide a variety of analog and digital analog conversion module products.
These modules have a variety of functions, in the connection of equipment, to achieve the greatest flexibility.
Can meet the inverter control, such as high-speed conversion needs.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location Q03UDCPU User's Manual.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
Transformer isolation between power supply and output.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module. MODBUS RTU/MODBUS ASCII Master slave station.
RS-232.
RS-422/485.
MODBUS interface module capable of connecting MODBUS compatible device such as temperature regulator, measuring device and so on.
Support MODBUS communication function, and can be compatible with the third party MODBUS to communicate from various station equipment.
Support MODBUS communication functions from the station, can communicate with the third party programmable controller MODBUS master device.
Through the linkage function, the master can be connected to the CH1 side (RS-232),
And through the QJ71MB91 and connected to the CH2 side (RS-422/485) of a number of stations for communication Q03UDCPU Manual.
The RS-232 interface (1 credit on the 1 pass) MODBUS master device withh multiple MODBUS communication from the station equipment Q03UDCPU Manual. (only QJ71MB91)
Master / slave station functions can be used simultaneously. (only QJ71MT91)
Related products
MITSUBISHI
With Ethernet CPU
Q03UDECPU
MITSUBISHI With Ethernet CPU Q03UDECPU
Input / output points: 4096 points. Numer of
MITSUBISHI
General high speed CPU
Q03UDVCPU
MITSUBISHI General high speed CPU Q03UDVCPU
Input / output points: 4096 points. Input / o
MITSUBISHI
Motion CPU module
Q173DCPU
MITSUBISHI Motion CPU module Q173DCPU
Control axis: maximum 32 axes. Manual pulse g
MITSUBISHI
Motion CPU module
Q172DCPU
MITSUBISHI Motion CPU module Q172DCPU
Control axis: maximum 8 axes. Peripheral I/F: