Product model: FR-D740-0.4K-CHT
Name: INVERTER
Brand: MITSUBISHI
Sort: BASIC Instruction manual
File language: English
File size: 12.44MB
Can be isolated to obtain DC24/48/100V, AC100/200V input signal.The connector is converted to a spring clip terminal row.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 110KW FR-D740-0.4K-CHT BASIC.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes FR-D740-0.4K-CHT
For the requirements of relatively high precision, even if the load changes are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection) FR-D740-0.4K-CHT BASIC.
If the given acceleration time is too short, the output frequency of the inverter is far more than the change of the speed (electric angular frequency),
Converter will be due to flow over the current trip, the operation stopped, which is called stall. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 5.5kw.
SLD converter rated current: 12 FR-D740-0.4K-CHT BASIC. 6A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control. Power supply: 110mA DC5V (PLC internal power supply), 90mA DC24V (external power supply).
Analog input points: 4 points.
Voltage input: DC-10~10V.
Current input: DC-20~20mA, 4~20mA.
Weight: 0.2kg.
Dimensions: 55 x 90 x 87.
Voltage iinput and current input of 4 channels can be carried out,
Each channel can be specified as a current input or voltage input FR-D740-0.4K-CHT Instruction manual.
Built in digital filter function and peak hold function, etc.,
Achieved a high speed of 500 AD S/ch conversion FR-D740-0.4K-CHT Instruction manual.
FX3U-4AD can connect FX3GA/FX3G, FX3GE, FX3U series.
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-IPS-5V.
Related products
MITSUBISHI
3 phase 400V converter
FR-D740-3.7K-CHT
MITSUBISHI 3 phase 400V converter FR-D740-3.7K-CHT
MITSUBISHI inverter FR-D740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-D740-0.75K-CHT
MITSUBISHI 3 phase 400V converter FR-D740-0.75K-CHT
MITSUBISHI inverter FR-D740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-D740-0.4K-CHT
MITSUBISHI 3 phase 400V converter FR-D740-0.4K-CHT
MITSUBISHI inverter FR-D740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-D740-7.5K-CHT
MITSUBISHI 3 phase 400V converter FR-D740-7.5K-CHT
MITSUBISHI inverter FR-D740 series. Voltage l