Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI F1-12MR-UL Manual F1-12MR-UL source input type INSTRUCTION MANUAL

MITSUBISHI F1-12MR-UL Manual F1-12MR-UL source input type INSTRUCTION MANUAL

Product model: F1-12MR-UL
Name: PLC
Brand: MITSUBISHI
Sort: source input type INSTRUCTION MANUAL
File language: English
File size: 3.18MB
Function extension board for RS-232C communication.
No DC24V consumption, no occupancy of the input output (FX1S and FX1N of the host computer). Max input / output points: 40 points.
Power supply voltage: 12-24VDC.
Input points: 24 points.
Output points: 16 points.
Output type: Transistor (source).
Power consumption (W): 18 F1-12MR-UL INSTRUCTION MANUAL.
Weight (kg):0.65.
Size (WxHxD) mm:130x90x75 F1-12MR-UL
Terminal row type standard machine with extended input output
Can also be less of a system with analog or communication, etc..
CPU, power supply, input and output integration.
Display module or function expansion board can be less installed.
In addition, you can also reduce the input output or special module.
Built in 8000 step EPROM memory F1-12MR-UL INSTRUCTION MANUAL.
No battery. Maintenance free.
Overseas oriented products meet all kinds of international standards.
FX1N series is a very powerful micro PLC, can be extended to up to 128 I/O points,
And can increase the special function module or the expansion board.
Communication and data link function options make FX1N in the volume, communication and special function modules and other important applications is very perfect F1-12MR-UL INSTRUCTION MANUAL.
A PLC unit can output 2 100KHz pulses at the same time,
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute position readout, absolute or relative drive, and special pulse output control. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 45KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes.
For the requirements of relatively high precision, even if the load changes are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection).
If the given acceleration time is too short, the output frequency of the inverter is far more than the change of the speed (electric angular frequency),
Converter will be due to flow over the current trip, the operation stopped, which is called stall. Power: 15kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistoor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling F1-12MR-UL Manual.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between thhe short circuit chip, in addition to connecting the DC reactor F1-12MR-UL Manual.
The installation of thermal relay, to avoid overheating and burn the braking resistor.