LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI AX20-UL Manual AX20-UL User's Manual

MITSUBISHI AX20-UL Manual AX20-UL User's Manual

Product model: AX20-UL
Name: PLC
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 0.41MB
Write adapter for EPROM 28 pinOptional features of memory card (Q/QnA/A/FX compatible).
4MB extended memory.
Applicable models: A985 (-V) /975/970/A960GOT (-B) /A956WGOT. Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive and negative sharing AX20-UL User's Manual.
Output points: 16 points.
Output voltage: DC24V/AC240V, 2A/1 point, 4A/ common end AX20-UL
Output response time: 12ms.
Output type: relay output.
8 point /1 a public side.
50 point terminal station.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points AX20-UL User's Manual.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process AX20-UL User's Manual.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points. Description: can form up to 8 of the star wiring, as well as the maximum length of the application of the transmission line distribution, waterproof (IP67) structure.
Spare 5 products for different purposes.
Thin waterproof type relay hub.
Extension of star type wiring and main line length, waterproof structure.

Spring clip terminal type relay hub AX20-UL Manual .
Star type wiring, length of the main line, spring clamping terminal table type.
Relay appliance (T branch) unit.
Extension of T type branch and trunk length.
Relay unit in light.
In the presence of interference in the environment of the wiring, the length of the trunk line AX20-UL Manual .
Relay unit in space light.
Communication between linear moving bodies.
Related products
MITSUBISHI
Input module
AX21C
MITSUBISHI Input module AX21C
Input points: 32 points. Input voltage: AC200
MITSUBISHI
Input module
AX21EU
MITSUBISHI Input module AX21EU
Input points: 32 points. Voltage: AC200 240
MITSUBISHI
Input module
AX20
MITSUBISHI Input module AX20
Input points: 16 points. Voltage: AC200 240
MITSUBISHI
Input module
AX21
MITSUBISHI Input module AX21
Input points: 32 points. Voltage: AC200 240