LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A6TE2-16SR Manual A6TE2-16SR User's Manual

MITSUBISHI A6TE2-16SR Manual A6TE2-16SR User's Manual

Product model: A6TE2-16SR
Name: Relay Terminal Unit
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 0.15MB
Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 10ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0 A6TE2-16SR User's Manual. 5A.
External connection: 2 line /2 line type.
Type of input and output terminal A6TE2-16SR
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module. Applicable model: A985GOT (-V).Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No A6TE2-16SR User's Manual.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 2 wire.
Spring clip terminal.
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module.
When installing the module can choose to use the DIN guide rail or screw mounting A6TE2-16SR User's Manual.
Can be used for the 3 wire sensor input wiring. A0J2 56.
Input / output unit 2
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. AnS, QnAS bus connection, the reader to write program 2 channel connection.Type of input: DC source.
Input points: 16 points.
Input voltage: DC24.
Input current: 7mA.
Connection mode: terminal row.
Common common point: 16.
Functional block diagram language is a kind of PLC programming language, which is similar to digital logic circuit.
The function module is used to represent the function of the module,
Different function modules have different functions.
Functional module figure programming language features: functional block diagram programming language is characterized by a functional module for the unit,
Analysis and understanding of the control schemme is simple and easy: function module is to use graphical form of expression,
Intuitive, for a digital logic circuit based on the design of the staff is very easy to master the programming;
Control system with complex scale and coomplex control logic,
Because the function module diagram can clearly express the function relation, the programming debugging time is greatly reduced A6TE2-16SR Manual A6TE2-16SR Manual.
Related products