Product model: A1SJ71E71N-T
Name: Hardware
Brand: MITSUBISHI
Sort: Hardware Hardware
File language: English
File size: 0.00MB
Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5mA.
External connection: 2 wire.
Type of input and output terminal.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module A1SJ71E71N-T Hardware A1SJ71E71N-T Analog channel: 16 channels.
Input / output (resolution): 0 ~ 4000.
Conversion speed: 100ms/16 channel.
Analog module installation.
Power supply: DC24V.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system A1SJ71E71N-T Hardware.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong A1SJ71E71N-T Hardware.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer. Twisted pair cable.
Single bus.
MELSECNET/B (Master / local station).
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC initialization procedure. Affter MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system A1SJ71E71N-T Hardware.
The main contents of the initialization program arre: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc A1SJ71E71N-T Hardware. .
Related products
MITSUBISHI
Serial communication module
A1SJ71QC24-R2
MITSUBISHI Serial communication module A1SJ71QC24-R2
RS-232 2 channel. Transfer speed: 0.3-19.2kp
MITSUBISHI
Computer communication module
A1SJ71UC24-R4
MITSUBISHI Computer communication module A1SJ71UC24-R4
Interface: RS422/485 Transmission distance: 5
MITSUBISHI
Ethernet module
A1SJ71QE71N-B5
MITSUBISHI Ethernet module A1SJ71QE71N-B5
10BASE5. Q mode. MITSUBISHI PLC is the main p
MITSUBISHI
Serial communication module
A1SJ71QC24
MITSUBISHI Serial communication module A1SJ71QC24
RS-232 1 channel. RS-422/485 1 channel. Trans