LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A0J2CPU Common Instructions Programming Manual

MITSUBISHI A0J2CPU Common Instructions Programming Manual

Product model: A0J2CPU
Name: Programmable Logic Controller
Brand: MITSUBISHI
Sort: Common Instructions Programming Manual
File language: English
File size: 3.29MB
MELSECNET/10, MELSECNET/H coaxial, input voltage: AC100-240V.RS-232:1 channel, RS-422:1 channel.
BASIC program mode (A3MCPU corresponding): BASIC console interface to use.
Sequential program mode (program controller CPU correspondence): non sequential computer connection interface and use.
How to choose MITSUBISHI PLC A0J2CPU Common Instructions.
MITSUBISHI PLC options include the choice of MITSUBISHI PLC models, capacity, I/O module, power, etc A0J2CPU.
MITSUBISHI PLC distribution I/O points and design MITSUBISHI PLC peripheral hardware circuit
Draw the I/O point of the PLC and the input / output device connection diagram or the corresponding table,
This part also can be carried out in second steps.
Design PLC peripheral hardware circuit A0J2CPU Common Instructions.
Draw the electrical wiring diagram of the other parts of the system,
Including the main circuit and the control circuit does not enter the PLC, etc..
The electrical schematic diagram of the system composed of I/O PLC connection diagram and PLC peripheral electrical circuit diagram.
So far the system''s hardware electrical circuit has been determined. Output points: 16 points.
Voltage: DC24V/AC240V, 2A/1 point, 16A/ all points A0J2CPU Common Instructions.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms.
All points of independence.
38 point terminal station.
With the surge absorber.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A singgle coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A0J2CPU Programming Manual A0J2CPU Programming Manual .
Related products
MITSUBISHI
General purpose CPU
Q13UDHCPU
MITSUBISHI General purpose CPU Q13UDHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
Programmable logic controller CPU
R32CPU
MITSUBISHI Programmable logic controller CPU R32CPU
Operation control mode: stored procedure repe
MITSUBISHI
CPU unit
A0J2CPUR23
MITSUBISHI CPU unit A0J2CPUR23
Input and output points: 480 points. Program